Drivers 5.8.0 · Device profiles 9.7.0
Published on 2026-11-04.
Breaking changes
An integration reading these points may need to be adapted.
| Driver | What changes |
|---|---|
spt-nkew:triphaso-542:1 | Output changes from a list of { n, v, u, t, rw } measurements (Energy Total, Power, Reactive Power...) to a flat object of EPM_* and PHASEABC_* fields plus the Watteco frame fields |
Point fields that change
| Driver | What changes |
|---|---|
sensaio:generic:1 | The warnings FLAG_ACCEL_FAILURE and FLAG_UNKNOWN are now FLAG_QOL and FLAG_DEGRADED_MODE; motion_position is signed (a raw 255 now reads -1). |
Point units and values that change
| Driver | What changes |
|---|---|
zenner:minomess-a-b-one:1 | The volume was decoded in liters but published as m3: the value is now divided by 1000. |
Drivers
dragino
| Driver | Change | What changed |
|---|---|---|
dragino:s31lbls:1 | added | Dragino S31-LB/LS and S31B-LB/LS: the manufacturer's v1.3 decoder with temperature, humidity and battery voltage points |
nke-watteco
| Driver | Change | What changed |
|---|---|---|
spt-nkew:triphaso-542:1 | updated | SPOT triphaso driver returns the decoded three-phase fields of the Watteco codec instead of the list of named measurements |
sensaio
| Driver | Change | What changed |
|---|---|---|
sensaio:generic:1 | updated | sensa.io decoder 1.3.3: motion position decoded as a signed value, status flags renamed |
zenner
| Driver | Change | What changed |
|---|---|---|
zenner:minomess-a-b-one:1 | updated | Minomess A B.One: volume points published in cubic meters, the module counts liters (a day value of 379 is now 0.379 m3) |
Device profiles
dragino
| Model | Change | What changed |
|---|---|---|
dragino:s31blbls:1 | added | Dragino S31B-LB/LS: new model (probe built into the case), with the manufacturer's decoder |
dragino:s31lbls:1 | added | Dragino S31-LB/LS: new model (external SHT31 probe), with the manufacturer's decoder |
itron
| Model | Change | What changed |
|---|---|---|
itron:cyble-5:1 | updated | Itron Cyble 5: single model for the LoRaWAN 1.0.2 and 1.0.4 profiles, told apart by their name (LoRaWAN 1.0.2, LoRaWAN 1.0.4, LoRaWAN 1.0.4 with extended frame repetition) — The profiles of Cyble 5 V2 and Cyble 5 V2.1 now belong to this model with unchanged profile ids; only their display names change. |
itron:cyble5-v2:1 | removed | Itron Cyble 5 V2 merged into the Cyble 5 model (LoRaWAN 1.0.4 profiles, same profile ids) |
itron:cyble5-v21:1 | removed | Itron Cyble 5 V2.1 merged into the Cyble 5 model (LoRaWAN 1.0.4 extended frame repetition profiles, same profile ids) |
itron:intelis:1 | added | Itron Intelis wSource: new water meter model, with the Cyble 5 LoRaWAN 1.0.4 profiles for EMEA and APAC and the extended frame repetition profile for EMEA |