Skip to main content

Drivers 5.8.0 · Device profiles 9.7.0

Published on 2026-11-04.

Breaking changes​

An integration reading these points may need to be adapted.

DriverWhat changes
spt-nkew:triphaso-542:1Output changes from a list of { n, v, u, t, rw } measurements (Energy Total, Power, Reactive Power...) to a flat object of EPM_* and PHASEABC_* fields plus the Watteco frame fields

Point fields that change​

DriverWhat changes
sensaio:generic:1The warnings FLAG_ACCEL_FAILURE and FLAG_UNKNOWN are now FLAG_QOL and FLAG_DEGRADED_MODE; motion_position is signed (a raw 255 now reads -1).

Point units and values that change​

DriverWhat changes
zenner:minomess-a-b-one:1The volume was decoded in liters but published as m3: the value is now divided by 1000.

Drivers​

dragino​

DriverChangeWhat changed
dragino:s31lbls:1addedDragino S31-LB/LS and S31B-LB/LS: the manufacturer's v1.3 decoder with temperature, humidity and battery voltage points

nke-watteco​

DriverChangeWhat changed
spt-nkew:triphaso-542:1updatedSPOT triphaso driver returns the decoded three-phase fields of the Watteco codec instead of the list of named measurements

sensaio​

DriverChangeWhat changed
sensaio:generic:1updatedsensa.io decoder 1.3.3: motion position decoded as a signed value, status flags renamed

zenner​

DriverChangeWhat changed
zenner:minomess-a-b-one:1updatedMinomess A B.One: volume points published in cubic meters, the module counts liters (a day value of 379 is now 0.379 m3)

Device profiles​

dragino​

ModelChangeWhat changed
dragino:s31blbls:1addedDragino S31B-LB/LS: new model (probe built into the case), with the manufacturer's decoder
dragino:s31lbls:1addedDragino S31-LB/LS: new model (external SHT31 probe), with the manufacturer's decoder

itron​

ModelChangeWhat changed
itron:cyble-5:1updatedItron Cyble 5: single model for the LoRaWAN 1.0.2 and 1.0.4 profiles, told apart by their name (LoRaWAN 1.0.2, LoRaWAN 1.0.4, LoRaWAN 1.0.4 with extended frame repetition) — The profiles of Cyble 5 V2 and Cyble 5 V2.1 now belong to this model with unchanged profile ids; only their display names change.
itron:cyble5-v2:1removedItron Cyble 5 V2 merged into the Cyble 5 model (LoRaWAN 1.0.4 profiles, same profile ids)
itron:cyble5-v21:1removedItron Cyble 5 V2.1 merged into the Cyble 5 model (LoRaWAN 1.0.4 extended frame repetition profiles, same profile ids)
itron:intelis:1addedItron Intelis wSource: new water meter model, with the Cyble 5 LoRaWAN 1.0.4 profiles for EMEA and APAC and the extended frame repetition profile for EMEA