DriverChangeWhat changed
msight:am304l:1updatedMilesight AM304L: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:am305l:1updatedMilesight AM305L: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:am319-hcho-ir:1updatedMilesight AM319-HCHO-IR: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:am319-hcho-well:2updatedMilesight AM319-HCHO-WELL: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:am319-hcho:1updatedMilesight AM319-HCHO: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:am319-o3:1updatedMilesight AM319-O3: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:cth01-compress:1updatedMilesight CTH01-COMPRESS: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 1 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (device_status). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:cth01:1updatedMilesight CTH01: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 1 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (retrieve_historical_data_by_time_range). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:em310-tilt:2updatedMilesight EM310-TILT: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:em320-tilt:2updatedMilesight EM320-TILT: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:em500-udl:1updatedMilesight EM500-UDL: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:gs601:3updatedMilesight GS601: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 30 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (buzzer_sleep, daylight_saving_time, humidity_calibration_settings, oem_id, pm1_0_calibration_settings, pm10_calibration_settings). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:ts201:2updatedMilesight TS201: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:ts301:2updatedMilesight TS301: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:ts601:2updatedMilesight TS601: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 39 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (button_lock, collection_interval, daylight_saving_time, humidity_alarm_settings, humidity_calibration_settings, humidity_mutation_alarm_settings). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:ts602:2updatedMilesight TS602: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 39 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (button_lock, collection_interval, daylight_saving_time, humidity_alarm_settings, humidity_calibration_settings, humidity_mutation_alarm_settings). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:uc100:2updatedMilesight UC100: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:uc511:2updatedMilesight UC511: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:uc512:2updatedMilesight UC512: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:uc521:1updatedMilesight UC521: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:uc711:1updatedMilesight UC711: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 14 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (anti_freezing, energy_saving, oem_id, target_temperature_range, target_temperature_settings, target_temperature_tolerance). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:vs351:2updatedMilesight VS351: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:vs370:1updatedMilesight VS370: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:vs373:2updatedMilesight VS373: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 4 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (delete_region). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:ws501:2updatedMilesight WS501: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 1 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (cancel_delay_task). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:ws502:2updatedMilesight WS502: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 1 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (cancel_delay_task). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:ws503:2updatedMilesight WS503: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 1 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (cancel_delay_task). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:ws523:1updatedMilesight WS523: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:ws525:1updatedMilesight WS525: BACnet write link groups follow the codec references — The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping. The decoder, the points and the write objects are unchanged.
msight:wt101:2updatedMilesight WT101: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 3 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (target_temperature, temperature_tolerance, dst_config). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:wt102:2updatedMilesight WT102: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 54 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (anti_freeze_protection_setting, auto_away_settings, daylight_saving_time, heating_period_settings, oem_id, temp_control). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:wt201:3updatedMilesight WT201: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 42 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (plan_type, d2d_master_enable, fan_execute_time, fan_dehumidify, humidity_range, temperature_dehumidify). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:wt303:3updatedMilesight WT303: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 86 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (celsius_target_temperature_tolerance, child_lock, collection_interval, cooling_target_temperature_range, daylight_saving_time, di_settings). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:wt304:3updatedMilesight WT304: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 88 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (celsius_target_temperature_tolerance, child_lock, collection_interval, cooling_target_temperature_range, daylight_saving_time, di_settings). Their R twin, the decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.
msight:wt401:2updatedMilesight WT401: codec writes the encoder accepts exposed as RW in the BACnet/Modbus mapping — 67 more write point(s) exposed through BACnet and Modbus with their downlink vocabulary (ble_configuration_settings, ble_name, children_lock_settings, daylight_saving_time, fan_enable, oem_id). The 4 text points that were declared both read-only and read/write (Bluetooth name parts, ble_name, oem_id) are now one read/write object each, as a BACnet character string is a single object. The decoder and the points are unchanged. The write link groups follow the codec reference of each field (the field and the points it lists, written together), not an inferred grouping.