Troubleshooting
No uplink in TPE
Resolve the radio, network, or device issue in TPE first. Netmore Go cannot display data that TPE is not receiving.
Recommended checks:
- Confirm that the device has joined the LoRaWAN network.
- Check for uplinks in the TPE Wireless Logger.
- Verify that the device is associated with the Netmore Go connection.
- Check the connection health and packet activity.
The Netmore Go device is empty
- Compare the DevEUI in TPE and Netmore Go. The values must match exactly.
- Confirm that Netmore ThingPark is selected as the Network Server.
- Check the device Debug Log to confirm whether data is arriving.
- Verify that the decoder is configured correctly.
Data arrives, but values are missing or incorrect
- Check the selected product or template.
- Check the payload decoder.
- Check the field mapping.
- Review the device Debug Log for decoder errors or unexpected output.
Diagnostic sequence
Use the following order to isolate the issue:
- TPE device traffic: Is TPE receiving uplinks?
- TPE connection assignment: Is the device associated with the Netmore Go connection?
- TPE connection activity: Is the connection active and forwarding packets?
- Netmore Go identity: Does the Netmore Go DevEUI exactly match the TPE DevEUI?
- Netmore Go Debug Log: Is data reaching the device record?
- Product decoder and fields: Is the payload decoded into the expected fields?
- Dashboard configuration: Are the widgets using the correct fields and time range?
See also Reference links.