SOS setup
Turn on SOS of the tracker:
Byte 0 | Byte 1 |
---|---|
0x04 | ACK |
Turn off SOS of the tracker:
Byte 0 | Byte 1 |
---|---|
0x05 | ACK |
ACK: Acknowledge token. Refer to the section Acknowledge token. Max value is 0x0F.
Refer to the section SOS to have more information about the SOS behavior.