Operational mode configuration

The operating mode can be remotely configured with a downlink LoRaWAN™ message built as follow:

Byte 0Byte 1Byte 2
0x02ACKMode

ACK: Acknowledge token. Refer to the section Acknowledge token Max value is 0x0F.

Mode: operating modes. Acceptable values are:

  • 0- Standby
  • 1- Motion tracking
  • 2- Permanent tracking
  • 3- Motion start/end tracking
  • 4- Activity tracking
  • 5- Off mode

Example

Changing the operating mode to "motion track" (01) with an ack token of 3: 0x020301.

Notes
  1. There is an additional way to update the operational mode based on a special configuration parameter. See here for more details