Skip to main content

Status message

The Status message provides various information on the tracker, mainly about power consumption and battery voltage. The Additional Data field defines the type of the Status message.

Common headerCommon headerCommon headerStatus information data
Byte 0Byte 1-3Byte 4
Type=0x04Status/Batt/Temp.ACK / Opt

Opt: message type

  • 0: Power status
  • 1: Health status

Power Status message

Common header with Type=0x04 and Opt=0x0.
This message is no longer used since the battery percentage is given in all uplinks for all trackers.

Health Status message

It is sent in answer to a health status request (see Status request for more details) Common header with Type=0x04 and Opt=0x1 power status data

Byte 5-6Byte 7Byte 8Bytes 9-10Bytes 11-12Bytes 13-14Bytes 15-16Bytes 17-18
Total powerMax temp.Min temp.LoRa power consumptionBLE power consumptionGPS power consumptionWIFI power consumptionBatt voltage
  • Total Power: total consumption value expressed in mAh
  • Max temp.: Max measured temperature in °C, encoded like the temperature in the header
  • Min temp.: Min measured temperature in °C, encoded like the temperature in the header
  • LoRa Power Consumption: accumulated consumption for the Lora radio, expressed in mAh
  • BLE Power Consumption: accumulated consumption for the BLE, expressed in mAh
  • GPS Power Consumption: accumulated consumption for the GPS, expressed in mAh
  • WIFI Power Consumption: accumulated consumption for the WIFI, expressed in mAh